Glass Upgrade Energy Saving Model

Commercial glazing performance model

Save Energy Charges through Upgrading Your Glass.

Copyright © Dortech Maintenance 2026This model is proprietary to Dortech Maintenance and must not be copied or reproduced

Have you considered upgrading your commercial glazing?

Modern, high-performance glass can refresh your building’s appearance, improve comfort for occupants and help reduce energy costs. Better insulation and solar control can also support more consistent internal temperatures.

Our Commercial Glazing Energy-Saving Calculator provides an indicative annual saving range in three simple steps:

  1. Tell Us About Your Current Glazing Select the glazing type, enter the approximate area and confirm whether the building is air-conditioned.
  2. Choose Your Glass Upgrade Compare your existing glazing with high-performance solar-control glass.
  3. Get Your Results View your indicative annual energy-saving range and explore the potential benefits.

Your result provides a practical starting point for discussing the most suitable glazing upgrade with Dortech Maintenance.

Tell Us About your Current Glazing

Existing Glass Type
Use this for plain older double-glazed units with no obvious body tint.
Glazed Area
m² Enter the approximate total glazed area being considered for replacement.
Building Type
Select this where active cooling is used for comfort or temperature control.
Confirm or Amend Energy Charges
p/kWh Default: 5.065p/kWh, based on the supplied 2026 gas quote of £5,926 over 117,000kWh. Adjust this if the client has a different commercial gas tariff.
p/kWh Default: 23.064p/kWh, based on the supplied 2026 electricity quote of £17,298 over 75,000kWh. Used for avoided air-conditioning load in cooled buildings.

Choose your Glass Upgrade

Stage 5: New Glass Type
Stage 6: Warm Edged Spacer?Stage 7: Glass Cavity ThicknessStage 8: Fine Tuning
New glass

Choose your desired Glass Specification:

Default selection. High light transmission with a low g-value and Ug-value of 1.0 W/m²K.
Ug-value 1.0 W/m²K
Light trans. 70% visible daylight
g-value 0.37 solar heat admitted
Warm edged spacer bar?
Standard spacer selected. Proposed glass assumes a nominal 16mm argon gas filled cavity unless the final project specification confirms otherwise.
mm Default 16mm argon-filled cavity. Changing this adjusts the indicative heating-side saving.

Performance values are shown from the selected manufacturer glass specification and are used by the indicative savings model. Guardian and Pilkington options are nearest public-data equivalents and should be checked against the final project make-up. Clayton Glass Triple28 uses the supplied PDF’s 0.8 W/m?K U-value; its LT and g-value are conservative placeholders until EN 410 optical data is confirmed.

Stage 8: Fine Tuning (Advanced Methodology Assumptions)
Advanced methodology assumptions — review before relying on the result

These values materially change the saving. Defaults keep the early-stage model usable when project data is unavailable; they are not surveyed facts or guaranteed UK-standard values. Replace them with project-specific evidence wherever possible.

Reference method: fabric heat saving uses ΔU × degree days × 24/1000. Cooling uses incident solar energy × Δg × cooling coincidence ÷ SSEER. UK government methodology confirms degree days are used with heat-loss coefficients; formal solar calculations require surface irradiance, g-value, orientation and shading. UK heat-demand method · GOV.UK solar-gain method · PVGIS site irradiance.

Selected scenario output

ScenarioAreaHeating savingCooling savingPotential annual saving
Clear Double Glazing Air Filled Cavity to Saint-Gobain COOL-LITE SKN 176250m2GBP 0GBP 0GBP 0

The model will update automatically as inputs change.

The annual result uses the visible advanced methodology assumptions and is not a formal building simulation. Replace placeholder inputs with survey, weather, orientation, shading, plant and tariff evidence before an investment decision.

Finance this project

Highest saving glass options for this scenario

 
Predicted ResultLive annual saving estimate
Heating saving £0 Based on reduced heat loss from Ug 2.7 to Ug 1.0.
Cooling saving range £0 Only applied where air conditioning is selected.
Total annual saving £0 Indicative annual saving per m².
Want to discuss upgrading your glass?

Contact Dortech Maintenance to talk through your existing glazing, building use, access requirements and the potential benefits of a modern glass upgrade.

Speak to our team now!
Advanced projection, methodology and finance details

Energy price trend and projected saving

This graph uses recent UK non-domestic gas and electricity prices as historic context, then applies a compound energy-price movement to the current calculator estimate. It helps show why a year-one saving may not remain flat if energy costs rise over time.

Historic energy-price context uses DESNZ Table 3.4.1 annual UK non-domestic prices, excluding Climate Change Levy. Future years are an illustrative compound projection from the calculator tariff inputs, not an official forecast. Source: DESNZ non-domestic energy prices.

Year Projected Saving (Midpoint) Cumulative Projected Savings Discount Factor Present Value
Projection updates automatically as the calculator changes.
Important — indicative, assumption-led model Manufacturer-declared EN 410 solar data and EN 673 centre-pane Ug-values are inputs only. The annual energy and cost outputs use user inputs plus clearly identified Dortech assumptions. They are not an EN 410 calculation, SBEM assessment, ISO 52016 simulation, investment recommendation, quotation or performance guarantee.

If the existing glass, heating efficiency, degree days, façade irradiance, orientation, shading, cooling controls or SSEER have not been verified, the result should be described only as an early-stage scenario. The PDF audit records every active assumption so it can be challenged and replaced with project evidence.

Model assumptions and evidence register

Use the status labels below to distinguish what came from the customer, what came from a manufacturer or public reference, and what Dortech has assumed to keep the early-stage model operable.

User inputPublished / referencedDortech assumptionCalculated result
Replacement glass — published inputThe selected centre-pane Ug, light transmission and g-value are taken from the relevant manufacturer reference make-up. Final project performance must be rechecked against the ordered make-up.
Heating theory — referenced method Annual useful heat reduction = (existing Ug − proposed Ug) × glazed area × heating degree days × 24 ÷ 1000. Estimated fuel reduction then divides by the entered seasonal heating efficiency and applies the gas tariff.
Cooling theory — referenced relationship, assumed boundary conditions Avoided cooling electricity = effective solar irradiation × (existing g − proposed g) × cooling coincidence ÷ SSEER × glazed area. Irradiation, coincidence and SSEER remain user-editable assumptions until supported by site evidence.
£2.70 benchmark explained It is no longer used as an unexplained stored cost. Under the defaults, 552 × (0.72 − 0.37) × 25% ÷ 3.0 × £0.168 = £2.70/m²/year (rounded). The high case is 552 × 0.35 × 45% ÷ 2.0 × £0.168 = £7.30/m²/year (rounded). The 552kWh/m²/year effective exposure was calibrated to reproduce the legacy Dortech £2.70/£7.30 scenario range; it is not an EN 410 value, published UK benchmark or measured project fact.
View the full assumption register, reasoning and evidence status
ItemStatusDefault / methodReasoning and required validation
Existing centre-pane Ug and g-valueDortech assumption with reference pointCategory-specific typical valuesUsed when the existing unit has not been identified. A local-authority retrofit guide gives indicative Ug reference ranges including single glazing 5–5.6, air-filled double glazing 2.8, argon-filled double glazing 2.6 and air-filled low-E double glazing 1.8W/m²K; the model’s existing g-values remain Dortech assumptions. Confirm from markings, records, glass analysis or survey. Reference values.
Proposed Ug, light transmission and g-valuePublished inputSelected manufacturer reference make-upEN 673 / EN 410 centre-pane data. Recalculate for the final pane thicknesses, laminate, coating surface, cavity, gas fill and inner pane. Reference families: Saint-Gobain SKN, Guardian SunGuard, Pilkington Suncool.
Cavity Ug adjustmentDortech assumptionInterpolated allowance from 6–24mm; 16–18mm = no upliftConvenience adjustment only. It is not a substitute for the manufacturer’s whole make-up calculation.
Heating degree daysUser-editable assumption2,000K·days/yearGeneric starting point using the degree-day heat-loss method. Replace with the building’s region, base temperature and operating schedule. Met Office / UKCP reference.
Heating system efficiencyUser-editable assumption85% seasonal efficiencyReference point only, not a surveyed plant value. Approved Document L says to prefer ETL/PCDB, manufacturer or boiler-plate evidence, then suitable SBEM defaults. Approved Document L, Appendix E.
Warm-edge spacer allowanceDortech assumption3% heating-side upliftPlaceholder for edge effects only. Validate using frame geometry, perimeter, linear thermal transmittance (Psi) and whole-window/curtain-wall calculation.
Effective annual solar irradiationUser-editable assumption552kWh/m²/yearCalibrated effective façade exposure selected to reproduce the legacy Dortech clear-to-SKN176 £2.70/£7.30 range because the model does not ask for location, orientation or shading. It is not a UK standard value. Replace with project-specific in-plane irradiance, for example from PVGIS or an approved hourly model.
Cooling coincidence / utilisationUser-editable assumption25% low case; 45% high caseRepresents how much of the reduced transmitted solar gain coincides with occupied hours and an active cooling demand. No occupancy, control or shading schedule is collected, so this remains a Dortech scenario assumption.
Cooling seasonal efficiencyUser-editable assumptionSSEER 3.0 low case; 2.0 high caseCooling electricity is cooling load divided by SSEER. Replace with actual plant data; system type, part-load performance, fans and controls can materially change the result.
Energy tariffsUser inputDefaults: gas 5.065p/kWh; electricity 23.064p/kWhConvenience defaults based on supplied 2026 quote data, not guaranteed current market rates. Replace with the customer’s invoice rates and account for taxes/levies consistently.
Five-year energy-price movementUser-editable assumption5% gas and 5% electricity per yearIllustrative compound escalation, not an official forecast. Historic DESNZ prices are context only.
Discount rateUser-editable assumption5% discount rateNPV discounts projected midpoint savings then subtracts the entered project cost. It does not include tax, maintenance, degradation, residual value or financing.

Formal-assessment boundary: EN 410 determines glazing solar/light characteristics; it does not by itself calculate annual building cooling savings. A formal assessment should use project geometry, orientation, shading, weather, occupancy, controls, internal gains and system performance in a method such as ISO 52016/SBEM or an appropriate dynamic simulation. ISO 52016-1 scope.

Optional business finance

Do you want to finance your reglazing project?

Click YES to view indicative finance calculations, Hexa Finance information and the dedicated PDF report.